    T-bone replied on May 07, 2008 02:29 to the question "Em100 doesnt work over full duplex network" in Tibbo:

    T-bone
    Hi,

    Our products work in auto-negotiate mode. It is not recommended to mix auto-negotiate and forced duplex mode together. The reason is that, the auto-negotiation will fail and the auto-negotiating device will default back to half-duplex.

    I have test it here using my computer and forcing my NIC to operate under 10BaseT/Full-Duplex, and I connected the DS100 directly to my computer via a CAT5 cable, it will still work, but when you introduce a whole LAN a lot of collision might occur which might cause the DS100 to not operate correctly.

    Another thing, make sure they are using 10BaseT not 100BaseT, DS100 only support 10BaseT.
  • question

    Mladen asked a question in Tibbo on May 06, 2008 13:46:

    Mladen
    Em100 doesnt work over full duplex network
    Hello,i have a problem that i need help with.

    When network adapter of laptop is configured as Auto mode the tibbo is visible via DS manager and works fine but when i try to change it to full duplex mode i lose tibbo completely
    on the network.
    The customer transfered from half to full duplex network and now all comunication with tibbo have stopped.